Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
J. bras. nefrol ; 43(2): 228-235, Apr.-June 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1286934

ABSTRACT

Abstract Introduction: Some authors advise in favor of delayed sampling of intraoperative parathormone testing (ioPTH) during parathyroidectomy in dialysis and kidney-transplanted patients. The aim of the present study was to evaluate the intensity and the role of delayed sampling in the interpretation of ioPTH during parathyroidectomy in dialysis patients (2HPT) and successful kidney-transplanted patients (3HPT) compared to those in single parathyroid adenoma patients (1HPT). Methods: This was a retrospective study of ioPTH profiles in patients with 1HPT, 2HPT, and 3HPT operated on in a single institution. Samples were taken at baseline ioPTH (sampling at the beginning of the operation), ioPTH-10 min (10 minutes after excision of the parathyroid glands), and ioPTH-15 min (15 minutes after excision of the parathyroid glands). The values were compared to baseline. Results: Median percentage values of ioPTH compared to baseline (100%) were as follows: 1HPT, ioPTH-10 min = 20% and ioPTH-15 min = 16%; 2HPT, ioPTH-10 min = 14% and ioPTH-15 min = 12%; 3HPT, ioPTH-10 min = 18% and ioPTH-15 min = 15%. Discussion: The reduction was equally effective at 10 minutes in all groups. In successful cases, ioPTH decreases satisfactorily 10 minutes after parathyroid glands excision in dialysis and transplanted patients, despite significant differences in kidney function. The postponed sampling of ioPTH appears to be unnecessary.


Resumo Introdução: Alguns autores aconselham a favor de se fazer uma amostragem tardia de teste de paratormônio intraoperatório (PTHIO) durante paratireoidectomia em pacientes transplantados renais e em diálise. O objetivo do presente estudo foi avaliar a intensidade e o papel da amostragem tardia na interpretação do PTHIO durante paratireoidectomia em pacientes em diálise (2HPT) e pacientes com transplante renal bem sucedido (3HPT) em comparação com aqueles em pacientes com adenoma único de paratireoide (1HPT). Métodos: Este foi um estudo retrospectivo dos perfis de PTHIO em pacientes com 1HPT, 2HPT, e 3HPT operados em uma única instituição. Foram coletadas amostras de PTHIO basal (amostragem no início da operação), PTHIO-10 min (10 minutos após a excisão das glândulas paratireoides), e PTHIO-15 min (15 minutos após a excisão das glândulas paratireoides). Os valores foram comparados aos resultados basais. Resultados: Os valores percentuais medianos do PTHIO em comparação aos basais (100%) foram os seguintes: 1HPT, PTHIO-10 min = 20% e PTHIO-15 min = 16%; 2HPT, PTHIO-10 min = 14% e PTHIO-15 min = 12%; 3HPT, PTHIO-10 min = 18% e PTHIO-15 min = 15%. Discussão: A redução foi igualmente eficaz aos 10 minutos em todos os grupos. Em casos de sucesso, o PTHIO diminui satisfatoriamente 10 minutos após a excisão das glândulas paratireoides em pacientes em diálise e transplantados, apesar das diferenças significativas na função renal. A amostragem tardia de PTHIO parece ser desnecessária.


Subject(s)
Humans , Parathyroidectomy , Hyperparathyroidism, Primary/surgery , Parathyroid Hormone , Retrospective Studies , Monitoring, Intraoperative , Renal Dialysis , Kidney
2.
Anest. analg. reanim ; 30(1): 62-95, jun. 2017. ilus
Article in Spanish | LILACS | ID: biblio-887208

ABSTRACT

El siguiente trabajo detalla un enfoque integral para la evaluación y el manejo intraoperatorio de la cirugía en la válvula mitral. Los avances tecnológicos han hecho de esta técnica un instrumento fundamental en el manejo intraoperatorio de estos pacientes. Las nuevas técnicas quirúrgicas de reparación de la válvula mitocondrial han determinado que el abordaje ecotransesofágico bi-dimensional se ha convertido en un examen de rutina, sin embargo, el advenimiento del ultrasonido tridimensional (3D) nos ha permitido aprender más sobre la anatomía funcional de la regurgitación de la válvula mitral, el mecanismo fisiopatológico predominante, y realizar evaluaciones en tiempo real de los resultados de una reparación o reemplazo quirúrgico. Estas contribuciones han contribuido a la capacidad de toma de decisiones de los equipos quirúrgicos, resultando en una mayor tasa de éxito para la reparación de la válvula mitral y una reducción de las complicaciones quirúrgicas.


The following work details an integral approach to the evaluation and intraoperative management of surgery on the mitral valve. Advances in technology have made this technique a fundamental instrument in the intraoperative management of these patients. The new surgical techniques of mitochondrial valve repair have determined that the bi-dimensional ecotransesophageal approach has become a routine examination, however, the advent of three-dimensional ultrasound (3D) has allowed us to learn more about the functional anatomy of the mitral valve's regurgitation, the predominant pathophysiological mechanism, and to conduct real-time evaluations of the results of a surgical repair or replacement. These contributions have contributed to surgical teams' decision-making capabilities, resulting in a greater success rate for mitral valve repair and a reduction of surgical complications.


O seguinte trabalho, faz uma abordagem integral da avaliação e manipulação intraoperatória da cirurgia na valva mitral. Os avanços na tecnologia tem feito dessa técnica um instrumento fundamental na manipulação intraoperatória desses pacientes. As novas técnicas cirúrgicas de reparação valvar mitral determinaram que a ecocardiografía transesofágica bidimensional tornou se um exame de rotina, no entanto o ultrassom tridimensional (3d) nos permitiu saber mais sobre a anatomia funcional da valva mitral, o mecanismo fisiopatológico predominante, assim como a avaliação em tempo real dos resultados da reparação ou substituição cirúrgica. Essas contribuições tem contribuído para a toma de decisões da equipe cirúrgica resultando numa maior taxa de sucesso de plastias da válvula mitral, assim como uma redução nas complicações cirúrgicas.


Subject(s)
Humans , Echocardiography, Transesophageal/statistics & numerical data , Intraoperative Period , Mitral Valve/surgery
3.
Arq. bras. neurocir ; 33(3): 170-175, set. 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-756168

ABSTRACT

A rizotomia dorsal seletiva é um procedimento cirúrgico bem aceito no manejo da espasticidade e tem como objetivo o alívio desse sintoma em pacientes cuidadosamente selecionados. Neste estudo, apresentamos o método que utilizamos em nosso serviço para indicação de pacientes, bem como a técnica cirúrgica e o método de monitorização neurofisiológica intraoperatória utilizado para otimizar os resultados. Realizamos também uma revisão bibliográfica utilizando os sites de busca da PubMed/MedLine e Lilacs, com artigos publicados entre os anos de 1965 e 2013. Os descritores utilizados foram: "rizotomia", "espasticidade", "paralisia cerebral" e "monitorização intraoperatória". Foram selecionados 17 artigos para este estudo.


Selective dorsal rhizotomy is a well-accepted cirurgic procedure utilized for relieving spasticity in carefully selected patients. In this work, we present the method we use to indicate the patients, the operative technique, and the intraoperative monitoring technique used in order to obtain the best results. We also reviewed the literature through the online databases PubMed/MedLine and Lilacs, with published papers from 1965 to 2013, descriptors included "rhizotomy", "spasticity", "cerebral palsy" and "intraoperative monitoring". We selected 17 articles for this study.


Subject(s)
Rhizotomy/methods , Rhizotomy/rehabilitation , Muscle Spasticity/complications , Muscle Spasticity/diagnosis , Patient Care Team , Monitoring, Intraoperative/methods
4.
Arq. bras. neurocir ; 33(1)mar. 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-721648

ABSTRACT

Our objective was to compeer the accuracy between two warning criteria during the intraoperative neurophysiologic monitorization for spine/spinal cord surgery. Method: We used two different warning criteria to detect neurological damage. The first criterion was the amplitude reduction of the somatossensory-evoked potentials (SEP) or motor-evoked potentials (MEP) greater than 50% at least in one limb and the second criterion was the complete loss of one of the same potentials. These results were compared with the neurological examination and the sensitivity, specificity, positive likelihood ratio (PLR) and negative likelihood ratio (NLR) was calculated for each criterion. Results: The sensitivity, specificity, PLR and NLR were respectively for criterion 1 and 2 (0,92/0,58; 0,96/0,99; 24/46 and 0,09/0,57). Conclusion: The first criterion suggests a better sensitivity and accuracy as a warning criterion to avoid central neurological damage...


Nosso objetivo foi comparar a acurácia entre dois critérios de alarme durante a monitorização neurofisiológica intraoperatória, em cirurgias de coluna ou medula. Método: Foram analisados dois critérios de alarme distintos para detectar danos neurológicos medulares, sendo o primeiro critério a redução maior que 50% na amplitude do potencial evocado somatossensitivo ou potencial evocado motor em pelo menos um membro. O segundo critério é a perda completa de um dos potenciais. Os achados foram comparados com as alterações neurológicas e a sensibilidade, especificidade, razão de verossimilhança positiva e negativa foram calculados para cada critério. Resultados: A sensibilidade, especificidade, razão de verossimilhança positiva e negativa foram, respectivamente, para os critérios 1 e 2 (0,92/0,58; 0,96/0,99; 24/46 e 0,09/0,57). Conclusão: O critério 1 aponta para uma tendência de melhor sensibilidade e acurácia, como sinal de alerta de um possível dano neurológico central...


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged, 80 and over , Spine/surgery , Monitoring, Intraoperative , Spinal Cord/surgery , Sensitivity and Specificity
5.
Coluna/Columna ; 11(4): 310-314, out.-dez. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-662454

ABSTRACT

OBJETIVO: Avaliar o uso da monitorização neurofisiológica intraoperatória (MNIO) por cirurgiões de coluna brasileiros. MÉTODO: A coleta de dados foi realizada através de um questionário aplicado em 307 cirurgiões de coluna brasileiros, durante o 11º Congresso de Cirurgia Espinhal e XIII Congresso da Sociedade Brasileira de Coluna. RESULTADOS: Dos cirurgiões entrevistados, 42% são neurocirurgiões e 58% ortopedistas. A maioria (72,3%) relatou que já fez uso do MNIO, entretanto apenas 29,6% utilizam este procedimento rotineiramente. Destes 39% são ortopedistas. Entre os neurocirurgiões, a maior parte (84%) relatou não utilizar MNIO como rotina. Nos casos de deformidade, 85,7% dos profissionais disseram usar rotineiramente a MNIO. Do total, 68,1% responderam que não tinham fácil acesso à MNIO, sendo que 10% deles atuam na região Centro-oeste do país e 11%, na região Nordeste. Dos que relataram facilidade de acesso ao procedimento, 77% atuam na região Sudeste. A média de idade dos participantes foi 41,9 anos, com mediana de 39,0, desvio padrão de 11,3 e intervalo de confiança de 1,3. Para o tempo de formação médica, a média foi 17,8 anos, com mediana de 14,0 e intervalo de confiança 1,2. Em relação ao tempo de prática em cirurgia de coluna encontrou-se que 56,3% têm até 10 anos de prática. CONCLUSÃO: A maioria dos cirurgiões de coluna já fez uso da MNIO, contudo poucos utilizam-na como rotina. A região Sudeste é onde se encontra maior facilidade de acesso à MNIO, ao contrário das regiões Centro-oeste e Nordeste.


OBJECTIVE: To assess the use of intraoperative neurophysiologic monitoring (MNIO) by Brazilian spine surgeons. METHOD: Data collection was conducted through a questionnaire applied to 307 spine surgeons during the 11º Congresso de Cirurgia Espinhal e XIII Congresso da Sociedade Brasileira de Coluna. RESULTS: Of the surgeons interviewed, 42% are neurosurgeons and 58% are orthopedists. Most of them (72.3%) reported that have already used MNIO, however, only 29.6% use this procedure routinely. 39% of them are orthopedists. Among neurosurgeons, most (84%) reported not using MNIO routinely. In cases of deformity, 85.7% of the professionals said they use routinely the MNIO. 68. 1% answered that did not have easy access to MNIO, of which 10% work in the Midwest region of the country and 11% in the Northeast. Of those who reported ease access to the procedure, 77% work in Southeast. The average age of the participants was 41.9 years, with a median of 39.0, standard deviation of 11.3 and a confidence interval of 1.3. For the medical training period, the average was 17.8 years, with a median of 14.0 and a standard deviation of 1.2. Regarding the length of practice in spinal surgery it was found that 56.3% are under 10 years of practice. CONCLUSION: The majority of spine surgeons have already used MNIO, yet few use it as a routine. The Southeast region is where there is easier access to MNIO, unlike the Midwest and Northeast.


OBJETIVO: Evaluar el uso del monitoreo neurofisiológico intraoperatorio (MNIO) por cirujanos de columna brasileños. MÉTODO: La recolección de datos fue realizada a través de un cuestionario aplicado en 307 cirujanos de columna brasileños, durante el 11º Congresso de Cirurgia Espinhal y el XIII Congresso da Sociedade Brasileira de Coluna. RESULTADOS: De los cirujanos entrevistados, el 42 % son neurocirujanos, y el 58 % son ortopedistas. La mayoría, el 72,3 %, relató que ya hacen uso del MNIO, mientras solamente el 29,6 % utilizan este procedimiento rutinariamente. De estos, 39 % son ortopedistas. Entre los neurocirujanos, la mayoría (84 %) relataron no utilizar MNIO como rutina. En los casos de deformidades, el 85,7 % de los profesionales dijeron que utilizan rutinariamente el MNIO; el 68,10 % respondieron que no tienen fácil acceso al MNIO, siendo que el 10% de ellos actúan en la región Centro-oeste del país y el 11% en el Nordeste. De los que reportaron la facilidad de acceso al procedimiento, el 77 % actúa en la región Sureste. La edad media de los participantes fue de 41,9 % años, mediana de 39,0, desviación estándar del 11,3 e intervalo de confianza de 1,3. Con respecto al tiempo de formación médica, la media fue de 17,8 años, con mediana de 14,0 e intervalo de confianza de 1,2. En duración de la práctica en cirugía espinal se encontró que el 56,3% tienen menos que 10 años de práctica. CONCLUSIÓN: La mayoría de los cirujanos de columna han hecho uso del MNIO, pero pocos lo utilizan como rutina. La región sureste es donde se encuentra mayor facilidad de acceso al MNIO, a diferencia de las regiones Centro-oeste y Nordeste.


Subject(s)
Humans , Spine/surgery , General Surgery/methods , Monitoring, Intraoperative , Surgeons/statistics & numerical data
6.
Einstein (Säo Paulo) ; 9(4)out.-dec. 2011. ilus
Article in English, Portuguese | LILACS | ID: lil-612040

ABSTRACT

Intraoperative neurophysiologic monitoring was performed in a patient by somatosensory evoked potential, motor evoked potential and free-running electromyography with intraoperative stimulation. It was verified that after decompression, there was an increase in the amplitude of motor evoked potential responses, showing an immediate improvement of the treated levels. Intraoperative neurophysiologic monitoring for surgical lumbar disc herniation in an athlete allowed a dynamic neurophysiological diagnosis, differentiation of the involvement of compression at the central or foraminal levels, and clinical awareness of the iatrogenic damage, thereby increasing safety.


Foi realizada em um paciente a monitorização intraoperatória neurofisológica com potencial somatossensitivo, motor e eletroneuromiografia contínua com estimulação intraoperatória. Depois da descompressão, ocorreu aumento da amplitude de resposta do potencial evocado motor, mostrando imediata melhora dos níveis tratados. A monitorização neurofisiológica intraoperatória para hérnia de disco lombar em um atleta permitiu um diagnóstico neurofisiológico dinâmico, diferenciação da compressão central ou foraminal e diagnosticar qualquer alteração iatrogênica aumentando a segurança.


Subject(s)
Humans , Male , Decompression, Surgical , Intervertebral Disc Displacement/surgery , Monitoring, Intraoperative
7.
Rev. méd. Minas Gerais ; 21(2 supl.3): 49-57, abri.-jun.2011. tab
Article in Portuguese | LILACS | ID: lil-786239

ABSTRACT

O índice bispectral (BIS) é um parâmetro multifatorial que permite a monitorização da componente hipnótico da anestesia. O BIS provê medidas quantificáveis do efeito de anestésicos no cérebro que correlacionam com a profundidade da anestesia. A monito-rização da profundidade anestésica na indução e manutenção da anestesia geral previne consciência e despertar intraoperatório, permite titular a quantidade de anestésicos adequada para promover a rápida recuperação da anestesia e evitar efeitos adversos da superdosagem dos fármacos. Desde sua introdução, a monitorização com BIS vem se tornando comum na prática anestésica. Esta revisão tem o objetivo de elucidar o papel do BIS na monitorização da hipnose na anestesia geral. Foi realizada revisão sobre o conceito de anestesia geral e monitorização da profundidade anestésica com o uso do BIS, bem como atualizações dos benefícios de seu emprego para a qualidade da anestesia, interpretação dos artefatos e drogas que podem interferir na sua utilização...


The bispectral index (BIS) is a multifactorial parameter that allows monitoring of the hypnotic component of anesthesia. The BIS provides quantitiable measures of the effect of anesthetics in the brain that correia te with the depth of anesthesia. Monitoring anesthetic depth during induction and maintenance of general anesthesia prevents intraoperative awakening and conscience and allows to holder the amount of anesthetic agents appropriate to promote a speedy recovery of anesthesia and avoid adverse effects of an overdose of drugs. Since its introduction, the BIS monitoring is becoming acommonplace in anesthetic practice. This review has the objective of elucidating the role of BIS monitor- ing in hypnosis of general anesthesia. A Literature review was conducted on the concepts of general anesthesia and monitoring of anesthetic depth using the BIS Moreover, recent articles on studies of BIS and its benetits in the quality of general anesthesia as well as the presence of artifacts and drugs that may interfere in its utilization...


Subject(s)
Humans , Anesthetics/administration & dosage , Intraoperative Awareness , Hypnosis, Anesthetic/instrumentation , Hypnotics and Sedatives/administration & dosage , Consciousness Monitors , Anesthesia, General/instrumentation , Electroencephalography/instrumentation , Image Processing, Computer-Assisted
8.
Arq. bras. neurocir ; 30(1)mar. 2011. tab
Article in Portuguese | LILACS | ID: lil-602481

ABSTRACT

A monitorização intraoperatória multimodal (MIOM) tornou-se um método amplamente utilizado para monitorização da função neural durante as cirurgias espinais. Um estudo prospectivo de 52 pacientes que foram monitorados durante os procedimentos cirúrgicos, entre outubro de 2009 e dezembro de 2010, no Hospital do Servidor Público Estadual de São Paulo, a fim de determinar a sensibilidade e especificidade das técnicas utilizadas para monitorar a medula espinhal e raízes nervosas durante as cirurgias espinais. Portanto, o objetivo deste estudo prospectivo foi avaliar a eficácia da MIOM, que inclui os potenciais evocados somatossensitivos (PESS), os potenciais evocados motores com estimulação transcraniana (MEPS), a eletromiografia contínua (EMG) captada nos músculos eletricamente estimulados a partir do córtex motor, na própria medula espinal, na cauda equina e nas raízes nervosas, comparando os dados eletrofisiológicos com os achados clínicos neurológicos no pós-operatório imediato. A MIOM visa monitorar tanto as vias ascendentes quanto as descendentes, fornecendo informações com feedback imediato sobre qualquer déficit neurológico durante o procedimento que permita uma identificação rápida de possíveis danos das estruturas neurais e prevenção por meio de ações corretivas. Técnicas que visam apenas avaliar as vias ascendentes ou as vias descendentes isoladamente não podem fornecer resultados com sensitividade ou especificidade adequados. Cinquenta e dois pacientes foram submetidos à MIOM. Desses, 49 casos foram verdadeiramente negativos, dois casos foram verdadeiramente positivos e 1 caso foi falso-positivo, resultando em sensibilidade de 100% e especificidade de 98% (p > 0,05). Não foram obtidos falsos-negativos. Com base nos resultados deste estudo, a MIOM é um método eficaz de monitorar a integridade funcional da medula espinal e, consequentemente, melhorar os resultados pós-operatórios.


Multimodal intraoperative monitoring (MIOM) has become a widely used method of monitoring neural function during spine surgery. A prospective study of 52 patients who received MIOM during spine surgery procedures between October 2009 and December 2010 at Hospital do Servidor Público Estadual de São Paulo, in order to determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve roots function during spine surgery. Therefore, the purpose of this prospective study was to evaluate the efficacy of somatosensory evoked potentials (SSEP), transcranial motor evoked potentials (MEP), and continuous electromyography (EMG) recorded from the spinal cord and muscles electrically elicited from the motor cortex, spinal cord, cauda equina and nerve root stimulation and compare the neurophysiological data with immediate post-operative clinical neurological outcome. MIOM aims to monitor both ascending and descending pathways, giving immediate feedback information regarding any neurological deficits during the operation allowing rapid identification of potential damage of the neural structures and avoidance through corrective action. Techniques that only evaluate either ascending or descending pathways, may not provide sensitive or specific results. Fifty two patients underwent MIOM to evaluate any neural deficits that may have occurred during spine surgery. Of these, 49 were true negative cases, 2 were true positive cases and 1 was false positive case, resulting in a sensitivity of 100% and a specificity of 98% (p > 0.05). None were false negative. Based on the results of this study, MIOM is an effective method of monitoring the spinal cord functional integrity and consequently improve postoperative results.


Subject(s)
Humans , Spine/surgery , Evoked Potentials , Monitoring, Intraoperative , Spinal Cord/surgery
9.
Coluna/Columna ; 9(3): 282-286, jul.-set. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-570581

ABSTRACT

OBJETIVO: apresentar a metodologia empregada na monitoração neurofisiológica de pacientes submetidos a tratamento para correção de escoliose idiopática com instrumentação cirúrgica, utilizando parafusos pediculares torácicos e lombares. MÉTODOS: foram estudados, retrospectivamente, 32 prontuários de pacientes operados no Serviço de Cirurgia da Coluna Vertebral do Instituto da Coluna,Jundiaí, São Paulo, entre os anos de 2004 e 2008. A idade variou de 11 a 18 anos, e a maioria era do sexo feminino (93,75 por cento). RESULTADOS: verificou-se que em seis pacientes houve relação entre a incidência de positividade no teste com estimulação eletromiográfica dos instrumentais e mau posicionamento dos parafusos pediculares, sem evidências de complicações após correção dos mesmos. CONCLUSÃO: os resultados confirmam a eficácia da monitoração intraoperatória.


OBJECTIVE: to present the methodology used for neurophysiological monitoring of patients undergoing idiopathic scoliosis correction with surgical instrumentation, using thoracic and lumbar pedicle screws. METHODS: retrospective study of the medical records of 32 patients submitted to surgery at the Spine Surgery Service of Instituto da Coluna, Jundiaí, São Paulo, Brazil, from 2004 to 2008. Ages ranged from 11 to 18 years, and the majority of the patients was female (93.75 percent). RESULTS: a correlation between positive clinical findings and pedicle screw malposition was found in six patients submitted to electromyographic stimulation instruments test, with no evidence of complications after correction of screw position. CONCLUSION: results confirm the efficacy of intraoperative monitoring.


OBJETIVO: presentar la metodología utilizada en la vigilancia neurofisiológica de los pacientes sometidos al tratamiento de corrección de la escoliosis idiopática, con el uso de instrumentación quirúrgica, utilizando tornillos pediculares torácicos y lumbares. MÉTODOS: se estudiaron 32 pacientes operados en el Servicio de Cirugía del Raquis del Instituto de la Columna (Jundiaí), en el Brasil, entre 2004 y 2008. Las edades oscilaban entre los 11 a 18 años y la mayoría era mujeres (93,75 por ciento). RESULTADOS: se ha detectado en seis pacientes la relación entre la incidencia de positivo en la prueba de estimulación con electromiografía de los instrumentales y la mala colocación de los tornillos pediculares, sin evidencias de complicaciones después de la corrección de los mismos. CONCLUSIÓN: los resultados confirman la eficacia de la monitorización intraoperatoria.


Subject(s)
Humans , Female , Adolescent , Bone Screws , Electromyography , Evoked Potentials, Motor , Monitoring, Intraoperative , Neurophysiology , Scoliosis
10.
Coluna/Columna ; 8(2): 197-199, abr.-jun. 2009. ilus
Article in Portuguese | LILACS | ID: lil-538724

ABSTRACT

Relatamos nota técnica para melhor visualização radiológica intraoperatória em cirurgias da região occipitocervical e coluna cervical superior.


We report a technical note to obtain a better intraoperative radiological view in surgeries of the craniocervical junction and upper cervical spine.


Relatamos nota técnica para mejor visualización radiológica intraoperatória en las cirugías de la región occipito-cervical y de la columna cervical alta.


Subject(s)
Humans , Atlanto-Axial Joint , Spine/surgery , Fracture Fixation , Joint Instability/rehabilitation , Cervical Vertebrae/surgery
11.
Rev. Assoc. Med. Bras. (1992) ; 55(4): 421-426, 2009. tab
Article in Portuguese | LILACS | ID: lil-525047

ABSTRACT

OBJETIVO: A hipotermia é prejudicial no período perioperatório. Não há consenso sobre o melhor método de aquecimento ativo e nem sobre o melhor período para fazê-lo. Este estudo teve como objetivo primário verificar a eficácia de diferentes períodos de utilização da manta térmica à temperatura de 38°C, como método de prevenção da hipotermia intraoperatória. Como objetivo secundário avaliou-se os efeitos adversos do uso da manta térmica na temperatura de 38°C. MÉTODOS: Foram comparados quatro grupos de 15 pacientes submetidos a operações ortopédicas. No grupo controle (Gcont) os pacientes não utilizaram manta térmica, nos grupos pré (Gpré), intra (Gintra) e total (Gtotal), os pacientes utilizaram manta térmica a 38ºC, respectivamente, durante 30 minutos antes da indução anestésica, após a indução anestésica até 120 minutos e antes e após a indução. Foram avaliados: temperatura central (timpânica), periférica (pele), da sala cirúrgica, variação das condições hemodinâmicas e efeitos adversos do aquecimento. RESULTADOS: O Gtotal foi o único grupo que não teve variação significativa da temperatura central. A temperatura central dos pacientes do grupo Gtotal foi significativamente maior (p <0,05) do que a dos outros grupos aos 60 e 120 min após a indução. Os pacientes dos grupos Gcont, Gpré e Gintra apresentaram hipotermia aos 60 min. CONCLUSÃO: O uso da manta térmica com fluxo de ar aquecido foi eficaz como método de prevenção da hipotermia intraoperatória quando foi empregada desde 30 min antes da indução anestésica até 120 min após o início da anestesia. Nas condições do estudo não ocorreram eventos adversos.


OBJECTIVE: Hypothermia is a life-threatening event during the perioperative period. No consensus has been reached about the best active warming approach for such cases. Furthermore there is no consensus on the most appropriate time to warm a hypothermic patient. This study aimed to assess the efficacy of a forced-air blanket to warm patients at 38ºC before and during surgery. Following utilization of the forced-air blanket, adverse effects were evaluated. METHODS: Patients submitted to orthopedic surgeries were divided into four groups of 15 patients. In the control group (Gcont), patients were not warmed with a forced-air blanket. In the preoperative group (Gpre), intraoperative group (Gintra), and total group (Gtotal), patients were warmed at 38°C, during 30 minutes before anesthetic induction, after anesthetic induction up to 120 minutes and before and after the induction, respectively. Parameters evaluated were central (tympanic) temperature, peripheral (skin) temperature, operating room temperature, variations in the hemodynamic conditions and warming-induced adverse effects. RESULTS: Only Gtotal did not show significant variation in central temperature. Central temperatures of Gtotal patients were significantly higher (p <0.05) than those of other groups at 60 and 120 min after induction. In Gcont, Gpre and Gintra, patients were hypothermic at 60 min. CONCLUSION: The forced-air blanket is effective to prevent intraoperative hypothermia when applied for a period ranging from 30 min before anesthetic induction to 120 min after anesthetic induction. In the conditions of this study, adverse effects were not observed.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Bedding and Linens , Hypothermia/prevention & control , Analysis of Variance , Anesthesia , Bedding and Linens/adverse effects , Intraoperative Period , Orthopedic Procedures , Skin Temperature/physiology , Time Factors , Tympanic Membrane/metabolism , Young Adult
12.
Rev. méd. Minas Gerais ; 17(1/2): 54-59, jan.-jun. 2007. tab, ilus
Article in Portuguese | LILACS | ID: lil-556273

ABSTRACT

A anestesia geral é o conjunto de vários estados fisiológicos, incluindo o estado de inconsciência. O receptor do ácido gama-aminobutírico, subtipo A, tem se revelado importante alvo de drogas anestésicas, na medida em que contribuiu para indução de sedação e inconsciência. O anestesiologista deve ter conhecimento dos mecanismos de ação dos fármacos na transmissão do sistema gabaérgico e saber utilizar os meios disponíveis para monitorizar a consciência do paciente anestesiado. Nesse contexto, os aparelhos que processam os sinais do eletroencefalograma têm se mostrado muito úteis na motorização da inconsciência.


Subject(s)
Humans , Consciousness , Anesthesia, General , Monitoring, Intraoperative , GABA Agents , Electroencephalography , Receptors, GABA
13.
São Paulo med. j ; 125(3): 186-190, May 2007. tab
Article in English | LILACS | ID: lil-463536

ABSTRACT

CONTEXT AND OBJECTIVE: Intraoperative nerve monitoring has emerged as a valuable tool to facilitate recurrent laryngeal nerve identification during thyroid surgery, thereby avoiding its injury. The aim was to evaluate vocal fold mobility in patients who underwent thyroidectomy with intraoperative nerve monitoring. DESIGN AND SETTING: Cohort formed by a consecutive series of patients, at a tertiary cancer hospital. METHODS: The subjects were patients who underwent thyroidectomy using intraoperative laryngeal nerve monitoring, between November 2003 and January 2006. Descriptive analysis of the results and comparison with a similar group of patients who did not undergo nerve monitoring were performed. RESULTS: A total of 104 patients were studied. Total thyroidectomy was performed on 65 patients. Vocal fold immobility (total or partial) was detected in 12 patients (6.8 percent of the nerves at risk) at the first postoperative evaluation. Only six (3.4 percent of the nerves at risk) continued to present vocal fold immobility three months after surgery. Our previous series with 100 similar patients without intraoperative nerve monitoring revealed that 12 patients (7.5 percent) presented vocal fold immobility at the early examination, and just 5 (3.1 percent) maintained this immobility three months after surgery, without significant difference between the two series. CONCLUSION: In this series, the use of intraoperative nerve monitoring did not decrease the rate of vocal fold immobility.


CONTEXTO E OBJETIVO: A monitorização intra-operatória de nervos surgiu como uma ferramenta valiosa para facilitar a identificação do nervo laríngeo recorrente durante a cirurgia de tireóide, evitando a sua lesão. O objetivo foi avaliar a mobilidade das pregas vocais em pacientes submetidos a tireoidectomia com monitorização intra-operatória do nervo laríngeo recorrente. TIPO E LOCAL DO ESTUDO: Coorte de uma série consecutiva de pacientes em um hospital terciário de tratamento de câncer. MÉTODOS: Pacientes foram submetidos à cirurgia de tireóide usando a monitorização intra-operatória do nervo laríngeo recorrente, entre novembro de 2003 e janeiro de 2006. Uma análise descritiva dos resultados e uma comparação com um grupo similar de pacientes que não foram submetidos a monitorização dos nervos foram realizadas. RESULTADOS: Um total de 104 pacientes foi estudado. Tireoidectomia total realizada em 65 pacientes. Imobilidade de pregas vocais (parcial ou total) foi detectada em 12 pacientes (6.8 por cento dos nervos sob risco) na primeira avaliação pós-operatória. Apenas 6 (3.4 por cento dos nervos sob risco) permaneceram com imobilidade de prega vocal três meses após a cirurgia. Nossa série prévia com 100 pacientes similares sem a monitorização intra-operatória revelou que 12 pacientes (7.5 por cento) apresentaram imobilidade de prega vocal na avaliação precoce, e apenas 5 (3.1 por cento) mantiveram a imobilidade três meses após a cirurgia, sem diferença significativa entre as séries. CONCLUSÃO: Nesta série, o uso da monitorização intra-operatória do nervo laríngeo recorrente não diminuiu a taxa de imobilidade de prega vocal.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Monitoring, Intraoperative/methods , Recurrent Laryngeal Nerve/injuries , Thyroidectomy/adverse effects , Vocal Cord Paralysis/diagnosis , Epidemiologic Methods , Monitoring, Intraoperative/statistics & numerical data , Postoperative Period , Recurrent Laryngeal Nerve/physiology , Vocal Cord Paralysis/epidemiology , Vocal Cord Paralysis/etiology
SELECTION OF CITATIONS
SEARCH DETAIL